Lenovo HX3510-G Installation And Service Manual page 518

Converged hx series server
Table of Contents

Advertisement

Prefix: PLAT ID: 0370
User Response
No action; information only.
• 806f0125-0c01ffff : [ManagedElementName] detected as absent. (Front Panel)
This message is for the use case when an implementation has detected a Managed Element is Absent.
May also be shown as 806f01250c01ffff or 0x806f01250c01ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0392
User Response
If there is no GPU/storage tray installed in the system, then the log event is a normal condition. If
there is a GPU/storage tray installed in the system, then check the following two portions:
1. PDB (Power Distribution Board) cable is correctly connected from riser card to PDB.
2. Replace another PDB cable.
• 806f0125-1001ffff : [ManagedElementName] detected as absent. (PCI Riser 1)
This message is for the use case when an implementation has detected a Managed Element is Absent.
May also be shown as 806f01251001ffff or 0x806f01251001ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
506
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide