3. Make sure that the heat sink for microprocessor n.
4. (Trained technician only) Replace system board.
80010902-0701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical)
has asserted. (SysBrd 12V)
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109020701ffff or 0x800109020701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0494
User Response
If the specified sensor is Planar 3.3V or Planar 5V, (Trained technician only) replace the system board.
If the specified sensor is Planar 12V, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. (Trained technician only) Replace the system board. (n = power supply number)
SysBrd 3.3V : SysBrd 5V :
80010b01-0701ffff : Numeric sensor [NumericSensorElementName] going high (upper
non-recoverable) has asserted. (RS1 RR Amb Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b010701ffff or 0x80010b010701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No