Lenovo HX3510-G Installation And Service Manual page 506

Converged hx series server
Table of Contents

Advertisement

• 806f010d-0413ffff : The Drive [StorageVolumeElementName] has been disabled due to a detected
fault. (Drive 19)
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
May also be shown as 806f010d0413ffff or 0x806f010d0413ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling
the drive) b. Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server
each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk
drive backplane (n = hard disk drive number)
• 806f010d-0414ffff : The Drive [StorageVolumeElementName] has been disabled due to a detected
fault. (Drive 20)
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
May also be shown as 806f010d0414ffff or 0x806f010d0414ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
494
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx5510-cHx7510Hx5510

Table of Contents