• Make sure that cables are not routed on top of components that are under the riser-card
assembly.
• Make sure that cables are not pinched by the server components.
Step 11. Align the riser-card assembly with the selected PCI connector on the system board and align it with
the slots on the chassis; then, lower it into the server and press down firmly until the riser-card
assembly is seated correctly in the connector on the system board.
• For half-length and low profile adapters (for HX7510 only)
Figure 86. Riser-card assembly installation - half-length and low profile adapters
• For full-height, full-length adapters (for HX3510-G only)
Note: Shipping brackets are only included in the server that is pre-configured with full-height,
full-length adapters
PCI riser-card assembly2
PCI riser-card assembly1
.
Chapter 5
Removing, and replacing components