Lenovo HX3510-G Installation And Service Manual page 516

Converged hx series server
Table of Contents

Advertisement

May also be shown as 806f01130302ffff or 0x806f01130302ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0224
User Response
1. Reseat the microprocessor, and then restart the server.
2. Replace microprocessor n. (n = microprocessor number)
806f011b-0701ffff : The connector [PhysicalConnectorElementName] has encountered a
configuration error. (Front USB)
This message is for the use case when an implementation has detected an Interconnect Configuration
Error.
May also be shown as 806f011b0701ffff or 0x806f011b0701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0266
User Response
Reset the front USB cable on the system board.
504
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx5510-cHx7510Hx5510

Table of Contents