Lenovo HX3510-G Installation And Service Manual page 400

Converged hx series server
Table of Contents

Advertisement

User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and
rear of the server), that the air baffle is in place and correctly installed, and that the server cover
is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. Replace the failed ML2 card.
• 8007010d-2582ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (RAID Vol State)
This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 8007010d2582ffff or 0x8007010d2582ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0520
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling
the drive) b. Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server
each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk
drive backplane (n = hard disk drive number)
8007010f-2201ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (GPT Status)
This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 8007010f2201ffff or 0x8007010f2201ffff
388
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide