Lenovo HX3510-G Installation And Service Manual page 368

Converged hx series server
Table of Contents

Advertisement

Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Reduce the ambient temperature.
2. Ensure the air baffle is installed correctly.
3. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
• 80010701-1402ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (CPU2 VR Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011402ffff or 0x800107011402ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Reduce the ambient temperature.
2. Ensure the air baffle is installed correctly.
3. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
• 80010701-1403ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (DIMM AB VR Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
356
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx5510-cHx7510Hx5510

Table of Contents