• 80010901-1401ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted. (CPU1 VR Temp)
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109011401ffff or 0x800109011401ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Reduce the ambient temperature.
2. Ensure the air baffle is installed correctly.
3. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
• 80010901-1402ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted. (CPU2 VR Temp)
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109011402ffff or 0x800109011402ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0