Lenovo HX3510-G Installation And Service Manual page 711

Converged hx series server
Table of Contents

Advertisement

Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0140
User Response
No action; information only. One of the DIMMs :
806f0813-2581ffff : An Uncorrectable Bus Error has occurred on system
[ComputerSystemElementName]. (DIMMs)
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
May also be shown as 806f08132581ffff or 0x806f08132581ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0240
User Response
1. Check the system-event log.
2. Check the DIMM error LEDs.
3. Remove the failing DIMM from the system board.
4. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
5. Make sure that the installed DIMMs are supported and configured correctly.
6. (Trained technician only) Replace the system board.
Appendix A. Integrated management module II (IMM2) error messages