Lenovo HX3510-G Installation And Service Manual page 467

Converged hx series server
Table of Contents

Advertisement

806f0021-2c01ffff : Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName]. (ML2 Card Fault)
This message is for the use case when an implementation has detected a Fault in a slot.
May also be shown as 806f00212c01ffff or 0x806f00212c01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0330
User Response
1. Check the PCI LED.
2. Reseat the affected adapters and riser card.
3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster
solutions require specific code levels or coordinated code updates. If the device is part of a
cluster solution, verify that the latest level of code is supported for the cluster solution before
you update the code.
4. Replace the affected adapters.
5. Replace the riser card.
6. (Trained service technicians only) Replace the system board.
806f0021-3001ffff : Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName]. (Internal RAID)
This message is for the use case when an implementation has detected a Fault in a slot.
May also be shown as 806f00213001ffff or 0x806f00213001ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Appendix A. Integrated management module II (IMM2) error messages
455

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx5510-cHx7510Hx5510

Table of Contents