Lenovo HX3510-G Installation And Service Manual page 363

Converged hx series server
Table of Contents

Advertisement

2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. (Trained technician only) Replace system board.
• 80010701-0702ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (RS2 RR Amb Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107010702ffff or 0x800107010702ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and
rear of the server), that the air baffle is in place and correctly installed, and that the server cover
is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. (Trained technician only) Replace system board.
• 80010701-0703ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (MID1 RR Amb Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107010703ffff or 0x800107010703ffff
Severity
Warning
Serviceable
Yes
Appendix A. Integrated management module II (IMM2) error messages
351

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx5510-cHx7510Hx5510

Table of Contents