4. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
5. (Trained technician only) Replace the system board.
• 80070204-0a01ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (PS 1 Fan Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702040a01ffff or 0x800702040a01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the
power-supply fan.
2. Replace power supply n. (n = power supply number)
• 80070204-0a02ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (PS 2 Fan Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702040a02ffff or 0x800702040a02ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Appendix A. Integrated management module II (IMM2) error messages