Lenovo HX3510-G Installation And Service Manual page 593

Converged hx series server
Table of Contents

Advertisement

Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions for that error event and restart the server.
3. Check the Lenovo support website for an applicable retain tip or firmware update that applies to
this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED
is lit, you can re-enable the DIMM through the Setup utility or the ToolsCenter Suite CLI.
806f040c-2010ffff : [PhysicalMemoryElementName] Disabled on Subsystem
[MemoryElementName]. (DIMM 16)
This message is for the use case when an implementation has detected that Memory has been Disabled.
May also be shown as 806f040c2010ffff or 0x806f040c2010ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions for that error event and restart the server.
3. Check the Lenovo support website for an applicable retain tip or firmware update that applies to
this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED
is lit, you can re-enable the DIMM through the Setup utility or the ToolsCenter Suite CLI.
Appendix A. Integrated management module II (IMM2) error messages
581

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx5510-cHx7510Hx5510

Table of Contents