Lenovo HX3510-G Installation And Service Manual page 644

Converged hx series server
Table of Contents

Advertisement

Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0446
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Recover the server firmware from the backup page by restarting the server.
3. Update the server firmware to the latest level (see Updating the firmware). Important: Some
cluster solutions require specific code levels or coordinated code updates. If the device is part
of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
4. Remove components one at a time, restarting the server each time, to see if the problem
goes away.
5. If the problem remains, (trained service technician) replace the system board.
• 806f0607-0301ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName]
has asserted. (CPU 1)
This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.
May also be shown as 806f06070301ffff or 0x806f06070301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0816
User Response
1. Make sure that the installed microprocessors are compatible with each other (see Installing a
microprocessor and heat sink for information about microprocessor requirements).
2. Update the server firmware to the latest level (see Updating the firmware).
3. (Trained technician only) Replace the incompatible microprocessor.
632
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx5510-cHx7510Hx5510