Lenovo HX3510-G Installation And Service Manual page 661

Converged hx series server
Table of Contents

Advertisement

Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
• 806f060d-0418ffff : Array [ComputerSystemElementName] has failed. (Drive 24)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0418ffff or 0x806f060d0418ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
• 806f060d-0419ffff : Array [ComputerSystemElementName] has failed. (Drive 25)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0419ffff or 0x806f060d0419ffff
Severity
Error
Appendix A. Integrated management module II (IMM2) error messages
649

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx5510-cHx7510Hx5510

Table of Contents