Lenovo HX3510-G Installation And Service Manual page 643

Converged hx series server
Table of Contents

Advertisement

• 806f0513-2582ffff : A PCI SERR has occurred on system [ComputerSystemElementName]. (PCIs)
This message is for the use case when an implementation has detected a PCI SERR.
May also be shown as 806f05132582ffff or 0x806f05132582ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0234
User Response
1. Check the PCI LED.
2. Reseat the affected adapters and riser card.
3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster
solutions require specific code levels or coordinated code updates. If the device is part of a
cluster solution, verify that the latest level of code is supported for the cluster solution before
you update the code.
4. Make sure that the adapter is supported. For a list of supported optional devices, see
http://www.lenovo.com/serverproven/.
5. Remove both adapters.
6. Replace the PCIe adapters.
7. Replace the riser card.
806f052b-2101ffff : Invalid or Unsupported firmware or software was detected on system
[ComputerSystemElementName]. (IMM2 FW Failover)
This message is for the use case when an implementation has detected an Invalid/Unsupported
Firmware/Software Version.
May also be shown as 806f052b2101ffff or 0x806f052b2101ffff
Severity
Error
Serviceable
Yes
Appendix A. Integrated management module II (IMM2) error messages
631

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx5510-cHx7510Hx5510

Table of Contents