May also be shown as 810100020701ffff or 0x810100020701ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Voltage
SNMP Trap ID
13
CIM Information
Prefix: PLAT ID: 0477
User Response
No action; information only.
• 81010202-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
deasserted. (CMOS Battery)
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has deasserted.
May also be shown as 810102020701ffff or 0x810102020701ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0481
User Response
No action; information only. SysBrd 12V : SysBrd 3.3V : SysBrd 5V :
• 81010204-1d01ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
deasserted. (Fan 1A Tach)
Appendix A. Integrated management module II (IMM2) error messages