Lenovo HX3510-G Installation And Service Manual page 459

Converged hx series server
Table of Contents

Advertisement

Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0794
User Response
1. Make sure that one or more DIMMs are installed in the server, and resolve any other currently
existing memory errors.
2. If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, verify that
all DIMM connectors are enabled using the Setup utility or the ToolsCenter Suite CLI.
3. Re-Install all DIMMs verifying the correct population sequence, according to the service
information for this product.
4. Replace DIMMs.
5. Recover the server firmware from the backup page: a. Restart the server. b. At the prompt,
press F3 to recover the firmware. c. Update the server firmware on the primary page. Important:
Some cluster solutions require specific code levels or coordinated code updates. If the device is
part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
6. If the problem remains, (trained technician only) replace the system board.
Firmware Error : Sys Boot Status : X8 PCI 1 Firm : X8 PCI 2 Firm : X8 PCI 6 Firm : X8 PCI 7 Firm :
806f000f-220102ff : Subsystem [MemoryElementName] has insufficient memory for operation.
(ABR Status)
This message is for the use case when an implementation has detected that the usable Memory is
insufficient for operation.
May also be shown as 806f000f220102ff or 0x806f000f220102ff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0132