• 800b0008-1301ffff : Redundancy [RedundancySetElementName] has been restored. (Power Unit)
This message is for the use case when an implementation has detected Redundancy was Restored.
May also be shown as 800b00081301ffff or 0x800b00081301ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Redundant Power Supply
SNMP Trap ID
10
CIM Information
Prefix: PLAT ID: 0561
User Response
No action; information only.
• 800b0108-1301ffff : Redundancy Lost for [RedundancySetElementName] has asserted. (Power
Unit)
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b01081301ffff or 0x800b01081301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Redundant Power Supply
SNMP Trap ID
9
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Check the LEDs for both power supplies.
2. Follow the actions in Power-supply LEDs.
Appendix A. Integrated management module II (IMM2) error messages