About System Components
CRU
Description
Fan modules
Four fan modules for cooling the motherboard assembly
and installed components.
PCIe cards
Optional add-on PCIe cards that can expand the
functionality of the server.
Note -
HBA card and the optional Oracle PCIe NVMe switch
card are field replaceable units (FRUs) and should only
be serviced by authorized Oracle Service personnel.
PCIe risers
Houses and connects the PCIe cards.
Power supplies
Two fully redundant AC power supplies.

Related Information

"Field-Replaceable Units" on page 20
"Illustrated Parts Breakdown" on page 17
"Servicing CRUs That Do Not Require Server Power-Off" on page 63
"Servicing CRUs That Require Server Power-Off" on page 85
"Server Internal Cables" on page 21

Field-Replaceable Units

The following table lists the field-replaceable units (FRUs) in the server and directs you to the
replacement instructions.
FRU
Description
Processor and
Carries out the instructions of the system.
heatsink
Oracle Storage 12
HDD and SSD storage drives controller
Gb/s SAS PCIe
RAID HBA card
Oracle PCIe NVMe
NVMe storage drives controller
switch card
Disk backplane
Serves as the interface between storage drives and the
internal host bus adapter (HBA) card and Oracle PCIe
NVMe switch card.
DVD drive
DVD drive
Front indicator
Contains the front panel controls, indicators, and USB
module (FIM)
ports.
Motherboard
Provides connectors for the fans, DIMMs, processors,
assembly
PCIe risers, internal USB ports, and power supplies.
SAS cables
Provide signals and backup power between the disk
backplane and the super capacitor and the Oracle
Storage 12 Gb/s SAS PCIe RAID HBA.
20
Oracle Server X6-2 Service Manual • June 2016
The Oracle Storage 12 Gb/s SAS PCIe RAID
Replacement Instructions
"Servicing Fan Modules (CRU)" on page 75
"Servicing PCIe Cards (CRU)" on page 108
"Servicing PCIe Risers (CRU)" on page 97
"Servicing Power Supplies (CRU)" on page 80
Replacement Instructions
"Servicing Processors (FRU)" on page 120
"Servicing the Internal HBA Card (FRU)" on page 140
"Servicing the Oracle PCIe NVMe Switch Card
(FRU)" on page 137
"Servicing the Disk Backplane (FRU)" on page 150
"Servicing the DVD Drive (FRU)" on page 156
"Servicing the Front Indicator Module
(FRU)" on page 158
"Servicing the Motherboard (FRU)" on page 162
"Servicing the Internal HBA SAS Cable
assembly" on page 173