Oracle X6-2 Service Manual page 264

Table of Contents

Advertisement

Environmental Events
Messages and Descriptions
SNMP Trap: sunHwTrapTempCritThresholdExceeded
Oracle ILOM Event Message: Upper critical threshold exceeded
Severity and Description: Critical; A temperature sensor has reported that its value has gone
above an upper critical threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapTempCritThresholdDeasserted
Oracle ILOM Event Message: Upper critical threshold no longer exceeded
Severity and Description: Informational; A temperature sensor has reported that its value has
gone below an upper critical threshold setting or above a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapTempFatalThresholdExceeded
Oracle ILOM Event Message: Lower fatal threshold exceeded
Severity and Description: Critical; A temperature sensor has reported that its value has gone
above an upper fatal threshold setting or below a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapTempFatalThresholdDeasserted
Oracle ILOM Event Message: Lower fatal threshold no longer exceeded
Severity and Description: Informational; A temperature sensor has reported that its value has
gone below an upper fatal threshold setting or above a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapTempCritThresholdExceeded
Oracle ILOM Event Message: Upper critical threshold exceeded
Severity and Description: Critical; A temperature sensor has reported that its value has gone
above an upper critical threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapTempCritThresholdDeasserted
264
Oracle Server X6-2 Service Manual • June 2016
Component Name
/SYS/MB/T_IN_ZONE2
/SYS/MB/T_OUT_ZONE2
/SYS/PS[0-1]/T_OUT
/SYS/MB/T_IN_ZONE0
/SYS/MB/T_OUT_ZONE0
/SYS/MB/T_IN_ZONE1
/SYS/MB/T_OUT_ZONE1
/SYS/MB/T_IN_ZONE2
/SYS/MB/T_OUT_ZONE2
/SYS/PS[0-1]/T_OUT
/SYS/MB/T_IN_ZONE0
/SYS/MB/T_OUT_ZONE0
/SYS/MB/T_IN_ZONE1
/SYS/MB/T_OUT_ZONE1
/SYS/MB/T_IN_ZONE2
/SYS/MB/T_OUT_ZONE2
/SYS/T_AMB
/SYS/MB/T_CORE_NET01
/SYS/MB/T_CORE_NET23
/SYS/MB/T_IN_PS
/SYS/T_AMB
/SYS/MB/T_CORE_NET01
/SYS/MB/T_CORE_NET23
/SYS/MB/T_IN_PS
/SYS/MB/T_CORE_NET01
/SYS/MB/T_CORE_NET23
/SYS/MB/T_IN_PS
/SYS/MB/T_CORE_NET01

Hide quick links: