Memory Device Components - Oracle X6-2 Service Manual

Table of Contents

Advertisement

Monitoring System Components
Component Name (Oracle ILOM CLI
Targets)
/SYS/DBP
/SYS/DBP/HDD[0-x]
/SYS/DBP/HDD[0-x]/PRSNT
/SYS/DBP/HDD[0-x]/STATE
/SYS/DBP/HDD[0-x]/SERVICE
/SYS/DBP/HDD[0-x]/OK2RM
/SYS/DBP/NVME[0-x]
/SYS/DBP/NVME[0-x]/PRSNT
Related Information
"System Chassis Components" on page 253
"Cooling Unit Components" on page 255
"Memory Device Components" on page 256
"Power Unit Components" on page 257
"Processor Components" on page 258
"System Board Components" on page 259
"System Firmware Components" on page 261
"Hard Disk Drive Components" on page 262

Memory Device Components

The following table lists the memory device components.
256
Oracle Server X6-2 Service Manual • June 2016
IPMI Type
Description
FRU
Disk backplane FRU
Pseudo
Hard disk drives
Discrete sensor
Hard disk drive
presence
State sensor
Hard disk drive state
Indicator
Service Required
LED
Indicator
OK to remove
NVMe drives
Discrete sensor
NVMe drive
presence
Values (if applicable)
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
02h-DRIVE_FAULT
04h-PREDICTIVE_FAILURE
08h-HOT_SPARE
Color: Amber
Location: Hard disk drive
Off: Normal
On: Hard disk drive was
diagnosed as faulty
Color: Blue
Location: Hard disk drive
Off: Normal
On: OK to remove hard disk
drive
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT