Press the green-tabbed release lever on the PCIe riser to the closed (down)
position [3].
To secure the rear bracket on the PCIe card to the server, close the green-tabbed
8.
latch on the rear of the server chassis [4].
If the riser does not have a PCIe card installed in slot 3, install a PCIe slot filler panel
Note -
and close the green-tabbed latch to secure the PCIe slot filler panel.
9.
If there is a PCIe card installed in slot 3 of the riser, reconnect any external or
internal cables to the card.
10.
Return the server to operation.
a.   
Install the server top cover.
See
"Install the Server Top Cover" on page
b.   
Return the server to the normal rack position.
See
"Return the Server to the Normal Rack Position" on page
Reconnect the power cord to the server power supply and the data cables.
c.   
See
"Reconnect Data Cables and Power Cords" on page
d.   
Power on the server.
See
"Power On the Server" on page
Verify that the Power/OK status indicator is steady on.
11.
Use Oracle ILOM to clear the server PCIe riser fault.
If the PCIe riser fault message in Oracle ILOM is not cleared under Open Problems, you
must manually clear the fault in Oracle ILOM. For instructions for manually clearing a
PCIe riser fault, see the procedure "Clear Faults for Undetected Replaced or Repaired
Hardware Components" in the Oracle ILOM User's Guide for System Monitoring and
Diagnostics Firmware Release 3.2.x in the Oracle Integrated Lights Out Manager (ILOM) 3.2
Documentation Library at http://www.oracle.com/goto/ilom/docs.
Related Information
"Remove the PCIe Riser From PCIe Slots 3 and 4" on page 103
Install the PCIe Riser Into PCIe Slots 3 and 4