Messages and Descriptions
Oracle ILOM Event Message: event fault.memory.intel.mrc.unknown-errcode "An unknown
error code from the Memory Reference Code (MRC) has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.udimm-unsupported "An
unbuffered memory DIMM (UDIMM) has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.udimm-unsupported "An
unbuffered memory DIMM (UDIMM) has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.sodimm-unsupported "An
unsupported SODIMM has been detected in system."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.sodimm-unsupported "An
unsupported SODIMM has been detected in system."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.4gb-fused "An unsupported 4-gb
memory DIMM has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.4gb-fused "An unsupported 4-gb
memory DIMM has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.8gb-fused "An unsupported 8-gb
memory DIMM has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.8gb-fused "An unsupported 8-gb
memory DIMM has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Component Name
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
Monitoring Components and Identifying SNMP Messages