Messages and Descriptions
Severity and Description: Informational; A voltage sensor has reported that its value has gone
below an upper fatal threshold setting or above a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapVoltageCritThresholdExceeded
Oracle ILOM Event Message: Upper critical threshold exceeded
Severity and Description: Critical; A voltage sensor has reported that its value has gone above
an upper critical threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapVoltageCritThresholdDeasserted
Oracle ILOM Event Message: Upper critical threshold no longer exceeded
Severity and Description: Informational; A voltage sensor has reported that its value has gone
below an upper critical threshold setting or above a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapVoltageNonCritThresholdExceeded
Oracle ILOM Event Message: Upper noncritical threshold exceeded
Severity and Description: Minor; A voltage sensor has reported that its value has gone above an
upper noncritical threshold setting or below a lower noncritical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapVoltageOk
Oracle ILOM Event Message: Upper noncritical threshold no longer exceeded
Severity and Description: Informational; A voltage sensor has reported that its value is in the
normal operating range.
Related Information
"System Chassis Components" on page 253
■
"Cooling Unit Components" on page 255
■
"Disk Backplane Components" on page 255
■
"Memory Device Components" on page 256
■
"Power Unit Components" on page 257
■
"Processor Components" on page 258
■
"System Board Components" on page 259
■
"Hard Disk Drive Components" on page 262
■
Component Name
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
Monitoring Components and Identifying SNMP Messages
Power Events