Oracle X6-2 Service Manual page 94

Table of Contents

Advertisement

Identify and Remove the Failed DIMM
See
c.   
Attach an antistatic wrist strap to your wrist and then to a metal area on the
chassis.
See
Remove the server top cover.
d.   
See
2.
Identify and note the location of the failed DDR4 DIMM by pressing the Fault
Remind button on the motherboard (see
Button" on page
Failed DDR4 DIMMs are identified with a corresponding amber LED on the motherboard.
If the DIMM fault LED is off, the DIMM is operating properly.
If the DIMM fault LED is on (amber), then the DIMM has failed and should be replaced.
3.
To remove the failed DIMM do the following:
a.   
Rotate both DIMM socket ejectors outward as far as they will go (See
20).
The DIMM is partially ejected from the socket.
94
Oracle Server X6-2 Service Manual • June 2016
"Extend the Server to the Maintenance Position" on page
"Take Antistatic Measures" on page
"Remove the Server Top Cover" on page
92).
56.
59.
60.
"Using the Server Fault Remind