Install a PCIe Riser Into PCIe Slot 1 or 2
5.
Close the green-tabbed latch on the rear of the server chassis next to the
applicable PCIe slot to secure the rear bracket on the PCIe card to the server
chassis [3].
Note -
the green-tabbed latch to secure the filler panel.
6.
If there were any external cables connected to the PCIe card, reconnect them.
7.
Return the server to operation.
a.   
Install the server top cover.
See
b.   
Return the server to the normal rack position.
See
Reconnect the power cords to the server power supplies and reconnect the
c.   
data cables.
See
d.   
Power on the server.
See
Verify that the Power/OK status indicator is steady on.
8.
Use Oracle ILOM to clear the server PCIe riser fault.
If the PCIe riser fault message in Oracle ILOM is not cleared under Open Problems, you
must manually clear the fault in Oracle ILOM. For instructions for manually clearing a
PCIe riser fault, see the procedure "Clear Faults for Undetected Replaced or Repaired
Hardware Components" in the Oracle ILOM User's Guide for System Monitoring and
Diagnostics Firmware Release 3.2.x in the Oracle Integrated Lights Out Manager (ILOM) 3.2
Documentation Library at http://www.oracle.com/goto/ilom/docs.
Related Information
"Remove a PCIe Riser From PCIe Slot 1 or 2" on page 99
102
Oracle Server X6-2 Service Manual • June 2016
If the riser does not have a PCIe card installed, install a PCIe slot filler panel and close
"Install the Server Top Cover" on page
"Return the Server to the Normal Rack Position" on page
"Reconnect Data Cables and Power Cords" on page
"Power On the Server" on page
188.
193.
194.
191.