D: References - YASKAWA CIMR-JC4A0002BAA Quick Start Manual

J1000 compact v/f control drive 200 v class, three-phase input: 0.1 to 5.5 kw 200 v class, single-phase input: 0.1 to 2.2 kw 400 v class, three-phase input: 0.2 to 5.5 kw
Table of Contents

Advertisement

B.2 Parameter Table
u

d: References

Reference parameters are used to set the various frequency reference values during operation.
No.
Name
Frequency reference.
d1-01
Frequency
Source: b1-01 on page 88
<1>
Reference 1
d1-01 as the main frequency reference.
d1-02
Frequency
Frequency reference when digital input "Multi-Step
<1>
Reference 2
Speed Reference 1" (H1-oo = 3) is on.
d1-03
Frequency
Frequency reference when digital input "Multi-Step
<1>
Reference 3
Speed Reference 2" (H1-oo = 4) is on.
d1-04
Frequency
Frequency reference when digital inputs "Multi-Step
<1>
Reference 4
Speed Reference 1, 2" (H1-oo = 3 and 4) are on.
d1-05
Frequency
Frequency reference when digital input "Multi-Step
<1>
Reference 5
Speed Reference 3" (H1-oo = 5) is on.
d1-06
Frequency
Frequency reference when digital inputs "Multi-Step
<1>
Reference 6
Speed Reference 1, 3 " (H1-oo = 3 and 5) are on.
d1-07
Frequency
Frequency reference when digital inputs "Multi-Step
<1>
Reference 7
Speed Reference 2, 3" (H1-oo = 4 and 5) are on.
Frequency reference when multi-function input
d1-08
Frequency
"Multi-Step speed reference 1, 2, 3" (H1-oo = 3, 4,
<1>
Reference 8
5) are on.
Frequency reference when digital inputs "Jog
d1-17
Jog Frequency
Frequency Reference", "Forward Jog" or "Reverse
<1>
Reference
Jog." are on.
Sets the frequency reference upper limit as a
Frequency
percentage of maximum output frequency (E1-04).
d2-01
Reference
Output speed is limited to this value even if the
Upper Limit
frequency reference is higher. This limit applies to all
frequency reference sources.
Sets the frequency reference lower limit as a
Frequency
percentage of maximum output frequency (E1-04).
d2-02
Reference
Output speed is limited to this value even if the
Lower Limit
frequency reference is lower. This limit applies to all
frequency reference sources.
216
Description
d1: Frequency Reference
Use d1 parameters to configure the drive frequency reference.
Refer to Frequency Reference
d2: Frequency Upper and Lower Limits
Use d2 parameters to configure the frequency reference limits.
d3: Jump Frequency
Use d3 parameters to configure the drive Jump Frequency settings.
YASKAWA ELECTRIC TOEP C710606 26B YASKAWA AC Drive – J1000 Quick Start Guide
http://nicontrols.com
for instructions to use
Range Def. Mode
0.00
S
Hz
0.00
S
Hz
0.00
S
Hz
0.00
S
Hz
0.00 to
0.00
400.00
O
Hz
Hz
<2>
0.00
O
Hz
0.00
O
Hz
0.00
O
Hz
6.00
S
Hz
0.0 to
100.
O
110.0
0%
0.0 to
0.0%
O
110.0
Addr.
Pg.
Hex
280
97
281
97
282
97
283
97
284
285
286
287
292
289
28A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents