A.5 Drive Watt Loss Data
Heavy Duty (Carrier Frequency 8 kHz)
Model
Number
Rated
CIMR-Jo
Amps (A)
4A0007
5.5
4A0009
7.2
4A0011
9.2
206
Interior
Heatsink
Unit Loss
Loss (W)
(W)
81.0
30.7
84.6
32.9
107.2
41.5
YASKAWA ELECTRIC TOEP C710606 26B YASKAWA AC Drive – J1000 Quick Start Guide
http://nicontrols.com
Normal Duty (Swing PWM equal 2 kHz)
Total
Rated
Loss (W)
Amps (A)
111.7
6.9
117.5
8.8
148.7
11.1
Interior
Heatsink
Unit Loss
Loss (W)
(W)
58.5
28.4
63.7
31.4
81.7
46.0
Total
Loss (W)
86.9
95.1
127.7