YASKAWA CIMR-JC4A0002BAA Quick Start Manual page 62

J1000 compact v/f control drive 200 v class, three-phase input: 0.1 to 5.5 kw 200 v class, single-phase input: 0.1 to 2.2 kw 400 v class, three-phase input: 0.2 to 5.5 kw
Table of Contents

Advertisement

n
Transistor Input Signal Using +24 V Common/Source Mode
When controlling digital inputs by PNP transistors (+24 V common/sourcing mode), set the
DIP switch S3 to SOURCE and use an external 24 V power supply.
SOURCE
SINK
External
power supply
+24V
Figure 3.18 Source Mode: Sequence from PNP Transistor (+24 V Common)
YASKAWA ELECTRIC TOEP C710606 26B YASKAWA AC Drive – J1000 Quick Start Guide
Shielded cable
FWD Run/Stop
REV Run/Stop
External Fault N.O.
Fault reset
Multi-step speed 1
http://nicontrols.com
3.8 I/O Connections
S1
S2
S3
S4
S5
SINK
+24V
S3
SOURCE
SC
3
61

Hide quick links:

Advertisement

Table of Contents
loading