J1000 compact v/f control drive 200 v class, three-phase input: 0.1 to 5.5 kw 200 v class, single-phase input: 0.1 to 2.2 kw 400 v class, three-phase input: 0.2 to 5.5 kw
Table of Contents

Advertisement

No.
Name
Selects the carrier frequency
1 : 2.0 kHz
2 : 5.0 kHz
3 : 8.0 kHz
Carrier
4 : 10.0 kHz
C6-02
Frequency
5 : 12.5 kHz
Selection
6 : 15.0 kHz
7 : Swing PWM
8 to E : No setting possible
F: User defined (determined by C6-03 through
C6-05)
Carrier
C6-03 and C6-04 set upper and lower limits for the
C6-03
Frequency
carrier frequency.
Upper Limit
Note: Set C6-02 to F before setting C6-03.
Carrier
C6-04
Frequency
Lower Limit
The coefficient K depends on C6-03:
C6-03 ≥ 10.0 kHz: K = 3
10.0 kHz > C6-03 ≥ 5.0 kHz: K = 2
5.0 kHz > C6-03: K = 1
When C6-05 ≤ 6, C6-04 is disabled (makes the
carrier frequency C6-03 value).
Carrier
Frequency
Sets the relationship of output frequency to carrier
C6-05
Proportional
frequency when C6-02 = F.
Gain
<1>
Parameter can be changed during run.
<2>
Default setting value is dependent on parameter o2-04, Drive Model Selection and C6-01, Drive Duty Selection.
<3>
Default setting value is dependent on parameter C6-02, Carrier Frequency Selection.
YASKAWA ELECTRIC TOEP C710606 26B YASKAWA AC Drive – J1000 Quick Start Guide
Description
carrier frequency
C6-03
C6-04
output frequency
× (C6-05) × K
max output
frequency
http://nicontrols.com
Range Def. Mode
1 to F
1.0 to
15.0
output
frequency
E1-04
1.0 to
15.0
00 to 99
B.2 Parameter Table
Addr.
Pg.
Hex
<2>
S
224
<3>
O
225
<3>
O
226
<3>
O
227
95