YASKAWA CIMR-JC4A0002BAA Quick Start Manual page 32

J1000 compact v/f control drive 200 v class, three-phase input: 0.1 to 5.5 kw 200 v class, single-phase input: 0.1 to 2.2 kw 400 v class, three-phase input: 0.2 to 5.5 kw
Table of Contents

Advertisement

n
Multiple Drive Installation
When installing multiple drives into the same enclosure panel, mount the drives according to
Figure
2.2. When mounting drives with a minimum side-by-side clearance of 2 mm according
to
Figure
2.3, derating must be considered and parameter L8-35 must be set.
Parameter List on page
A
B
2 mm
A – Line up the tops of the
drives.
B – 30 mm minimum
Figure 2.3 Space Between Drives (Side-by-Side Mounting)
Note:
When installing drives of different heights in the same enclosure panel, the tops of the drives should line
up. Leave space between the top and bottom of stacked drives for cooling fan replacement if required.
Using this method, it is possible to replace the cooling fans later.
YASKAWA ELECTRIC TOEP C710606 26B YASKAWA AC Drive – J1000 Quick Start Guide
209.
B
http://nicontrols.com
2.2 Mechanical Installation
C
C
C – 100 mm minimum
D – Airflow direction
Refer to
D
2
31

Hide quick links: