Setting Value
V ( right position)
I ( left position)
No.
Parameter Name
Frequency ref.
(voltage/current)
H3-01
terminal A1 signal
level selection
YASKAWA ELECTRIC TOEP C710606 26B YASKAWA AC Drive – J1000 Quick Start Guide
Table 3.12 DIP Switch S1 Settings
Voltage input (0 to 10 V): default setting
Current input (4 to 20 mA or 0 to 20 mA)
Table 3.13 Parameter H3-01 Details
Description
Selects the signal level for terminal A1.
0: 0 to +10 V, unipolar input (negative
frequency reference values are zeroed)
1: 0 to +10 V, bipolar input (negative
frequency reference changes the direction)
2: 4 to 20 mA
3: 0 to 20 mA
http://nicontrols.com
3.9 Main Frequency Reference
Description
Setting
Default
Range
Setting
0 to 3
MEMOBUS
Register
0
410
63
3