Basic Settings

DAMAGE TO THE USB INTERFACE
Exclusively use a Hirschmann AutoConfiguration Adapter (ACA) to
configure the device via the USB interface. Other connectors may cause
damage to the interface or result in a faulty configuration.
Failure to follow these instructions can result in minor injury or
equipment damage.
The IP parameters must be entered when the device is installed for the first
time. The device provides the following options for configuring IP addresses:
AutoConfiguration Adapter
Input via the HiView or Industrial HiVision application. You find further
information about the applications HiView or Industrial HiVision on the
Internet at the Hirschmann product pages:
HiView
http://www.hirschmann.com/en/QR/INET-HiView
Industrial HiVision
http://www.hirschmann.com/en/QR/INET-Industrial-HiVision
Input via the V.24 interface
Configuration via BOOTP
Configuration via DHCP (Option 82)
You will find more information in the "Basic Configuration User Manual".
Default settings
Ethernet ports: link status is not evaluated (signal contact)
IP address: The device looks for the IP address using DHCP
Optical ports: Full duplex
TP ports: Autonegotiation
Management password:
user, password: public (read only)
admin, password: private (read/write)
Rapid Spanning Tree Protocol: activated
V.24 data rate: 9600 Baud
Installation OCTOPUS OS3
Release 01 02/2019