3.2 SNMPv1/v2 Access Setting

With this dialog you can select access via SNMPv1 or SNMPv2. In the state
on delivery, both protocols are activated. You can thus manage the device
with HiVision and communicate with earlier versions of SNMP.
Note: You need read-write access for this dialog.
In the "Index" column, you enter the current number to which the access
restriction applies.
Enter the password with which this computer may access the device in
the "Password" column. Please note that passwords are case-sensitive.
This password is independent of the SNMPv3 password.
In the "IP Address" column, you enter the IP address which may access
the device. No entry in this field, or the entry "0.0.0.0", enables access to
the device from computers with any IP address. In this case, the only ac-
cess protection is the password.
In the "IP Mask" column, much the same as with network masks, you can
select a group of IP addresses.
Example:
255.255.255.255: a single IP address
255.255.255.240 with IP address = 172.168.23.20:
the IP addresses 172.168.23.16 to 172.168.23.31.
42
3.2 SNMPv1/v2 Access Setting
RM Web L3P
Release 4.1 03/08