Allen-Bradley Kinetix 6000M User Manual page 71

Integrated drive-motor system
Table of Contents

Advertisement

1756-MxxSE Sercos
Interface Module
Logix Platform
(ControlLogix controller is shown)
Network Node Address
Switches (covers removed)
In the following example
single-wide axis modules and one IDM system. A sercos node address is not
assigned to the slot-filler or the IPIM module. However, the system identifies
both modules with slot locations.
Node addresses 02 and 05 are available for any of the IDM units, but to avoid
confusion, the node addressing for the IDM units was started at 20. Unlike axis
modules, each IDM unit has switches that determine its node address. In example
1, the IDM unit node addressing is sequential, but it doesn't have to be.
IMPORTANT
IMPORTANT
Figure 32 - Node Addressing Example 1
SERCOS interface
CP
OK
Tx (rear)
Rx (front)
Transmit
Receive
0 1
Base Node Address
Switches
MDF-SBxxxxx
IDM Unit
D
N
S1
S10
3
1
2
Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
(Figure
32), the Kinetix 6000 power rail contains two
Creating a duplicate node address between the axis modules mounted on the
power rail and the IDM system generates error code E50. Each node address on
the sercos ring must be unique within the range of 01...99.
Slot-filler modules must be used to fill any unoccupied slot on the power rail.
However, you can replace slot-filler modules with AM modules or the 2094-
BSP2 shunt module (maximum one 2094-BSP2 shunt module per power rail).
Sercos Fiber-optic Ring
0.1 m
(5.1 in.)
Receive
Transmit
20 = IDM unit 1
21 = IDM unit 2
S1
S1
S10
S10
Configuring the Kinetix 6000M System
Kinetix 6000 System
(5-axis power rail)
05 = Slot-filler module slot location
04 = AM module (axis 3) node address
03 = AM module (axis 2) node address
02 = IPIM module slot location
01 = IAM module (axis 1) base node address
22 = IDM unit 3
23 = IDM unit 4