Kinetix 6000M System Connector Data
42

EtherNet/IP Connectors

Two connectors are provided for firmware upgrades, troubleshooting, and
integration with Logix. The Ethernet ports also support a web browser interface
to provide access to status information for the IPIM module and IDM units.
EtherNet/IP Ports
Pin
Signal Description
1
Transmit+
2
Transmit-
3
Receive+
4
Reserved
5
Reserved
6
Receive-
7
Reserved
8
Reserved

IPIM Module Network Connector Pinouts

The IDM system network is routed by using 2090-CNSxPxS-AAxx cables. A
2090-CNSSPRS-AAxx or 2090-CNSSPSS-AAxx cable is required for
connection to the IPIM module. The connector type is B-coded M12.
IDM Network
Connector
Pin
Signal Description
1
Transmit (TX+) to IDM unit
2
Return (RX-) from IDM unit
3
Return (RX+) from IDM unit
4
Transmit (TX-) to IDM unit
5
Reference signal
Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
8-pin Control Module
Ethernet Connector
1
8
Signal Name
TD+
TD-
RD+
RD-
2
5
1
3
4
Signal Name
TX+
RTN RX-
RTN RX+
TX-