The Sercos Fiber-optic Ring

(ControlLogix controller is shown)
The sercos fiber-optic ring is connected by using the sercos receive (RX) and
transmit (TX) connectors. Refer to
for details. Refer to the documentation supplied with your Logix sercos interface
module or PCI card for connector locations.
Plastic cable is available in lengths up to 32 m (105.0 ft). Glass cable is available in
lengths between 50 m (164.2 ft) and 200 m (656.7 ft).
Connect the cable from transmit on the Logix module to receive on the first
IPIM module, then transmit to receive (module to module), and from transmit
on the last module back to receive on the Logix module.
ATTENTION: To avoid damage to the sercos RX and TX connectors use only
finger-tight torque when attaching the fiber-optic cables. Do not use a wrench
or any other mechanical assistance. For more information, refer to Fiber-optic
Cable Installation and Handling Instructions, publication 2090-IN010.
Clean the fiber-optic cable connectors prior to installation. Dust in the
IMPORTANT
connectors can reduce signal strength. For more information, refer to Fiber-
optic Cable Installation and Handling Instructions, publication 2090-IN010.
The IPIM module has fiber-optic cable connectors positioned identical to the
Kinetix 6000 (2094-BMxx-S) drives, the IPIM module uses the same fiber-optic
cable lengths as the drive modules.
In the following example
module are on the same sercos ring. The ring begins and ends at the 1756-M16SE
sercos module. IDM units connected to the IPIM module (not shown for
simplicity) are also part of this sercos ring.
Figure 25 - Fiber-optic Cable Example - Logix Platform with IPIM Module
1756-M16SE Sercos
Interface Module
Logix Platform
TM
SERCOS interface
CP
OK
Tx (rear)
Rx (front)
2094-BMxx-x Single-wide AM Modules
Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
Connecting the Kinetix 6000M System
Sercos Fiber-optic Connectors
(Figure
25), all of the drive modules and the IPIM
Sercos Fiber-optic Ring
2094-SEPM-B24-S IPIM Module
Chapter 5
on
page 41
0.1 m
(5.1 in.)
Kinetix 6000 System
(4-axis power rail)