Signal integrity is very important for successful operation of an integrated drive-
motor system. You must be sure that all cables are properly grounded through the
IPIM module to the ground plane of the Kinetix drive system.
• Verify that every cable shield directly connects to chassis ground.
• Clamp the exposed section of the hybrid cable shield in the cable (chassis)
ground connection on the drive. Refer to
Figure 21 - Hybrid Cable Shields
Cable insulation is removed to expose the
overall shield of the cable.

Apply the Cable Shield Clamp

The cable shield clamp assures a solid bond to the shield and secures the cable.
1. Depress the spring loaded clamp.
2. Position the exposed portion of the cable braid directly in line with the
clamp.
3. Release the spring, making sure the cable and cable braid are held secure by
the clamp.
Outer Insulation
Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
Connecting the Kinetix 6000M System
Apply the Cable Shield
DC+
Power Wires
PE
DC-
and Ground
42-
42+
CN-
CN+
Grouped Signal
SH2
Wires and Shields
RTN
OUT
SE1
SE2
SE-
SH3
Exposed Braid (under clamp)
Chapter 5
Clamp.
55