Figure 308. E5505A System Connections With Test Set Option 001 - Agilent Technologies e1420b User Manual

Phase noise measurement system
Hide thumbs Also See for e1420b:
Table of Contents

Advertisement

18
System Interconnections
NOTE:
E5500 software
License key
PC-Digitizer card
N5500A Opt 001
Test Set
SIGNAL INPUT
0 VDC MAX
MAXIMUM POWER
50 kHz -1600 MHz
+23 dBm + ATTEN
1.2 GHz-26.5 GHz
+10 dBm + ATTEN
+30 dBm MAX WITH
50 kHz - 26.5 GHz
ATTENUATOR
RF ANALYZER
POSSIBLE
OUTPUT POWER
+30 dBm
ANALYZER
POWER
50 Ω load
To PC
digitizer
Spectrum
analyzer
E5505a_opt001_conn_dia
14 Apr 04 rev 1
Figure 308 E5505A system connections with test set option 001
402
Oscilloscope
(recommended)
Indicates optional cable
To test set
rear panel
CHIRP source
Digitizer
input
PC
Digitizer
Display
Test set Opt. 001
GPIB
STATUS
RMT
LSN
TLK
SRQ
ACT
ERR
INPUT
REF INPUT
SIGNAL
NOISE
50 kHz - 1600 MHz
1.2 - 26.5 GHz
50
1 V Pk
0.01 Hz - 100 MHz
+15 dBm MIN
+7 dBm MIN
PHASE DET OUTPUT
MONITOR
FROM
TO
DOWNCONVERTER
DOWNCONVERTER
TUNE VOLTAGE
ANALYZER
OUT OF LOCK
<100 kHz
<100 MHz
50
20 mA MAX
To reference
source (optional)
To oscilloscope or
counter monitor
(optional)
Optional frequency
counter
GPIB
Test set Opt. 001
N5500A Opt 001
Test Set
RMT
INPUT
SIGNAL INPUT
SIGNAL
NOISE
0 VDC MAX
MAXIMUM POWER
50 kHz -1600 MHz
+23 dBm + ATTEN
1.2 GHz-26.5 GHz
50
+10 dBm + ATTEN
1 V Pk
+30 dBm MAX WITH
50 kHz - 26.5 GHz
0.01 Hz - 100 MHz
ATTENUATOR
PHASE DET OUTPUT
POSSIBLE
RF ANALYZER
MONITOR
OUTPUT POWER
+30 dBm
ANALYZER
ANALYZER
<100 kHz
<100 MHz
POWER
Optional reference
signal generator
output
Spectrum analyzer
GPIB
N5501A
Downconverter
SIGNAL
MAXIMUM POWER
SIGNAL INPUT
50 kHz -1600 MHz
0 VDC MAX
+23 dBm
MAXIMUM POWER
5 MHz-1 GHz
1.2 -26.5 GHz
+10 dBm
+10 dBm
1 GHz-6.6 GHz
+15 dBm
5 MHz -6.6 GHz
ANALYZER
FROM TEST SET
POWER
DC out
downconverted
tune voltage
(optional)
Downconverter
N5502A
Downconverter
GPIB
STATUS
GPIB
STATUS
RMT LSN TLK SRQ
ACT
ERR
LSN
TLK
SRQ
ACT
ERR
REF INPUT
INPUT
OUTPUT
50 kHz - 1600 MHz
1.2 - 26.5 GHz
SIGNAL INPUT
SIGNAL
RF ANALYZER
MAXIMUM POWER
+5 -
50 kHz -1600 MHz
0 VDC MAX
+15 dBm
MAXIMUM POWER
+23 dBm
5 MHz-1 GHz
1.2-26.5 GHz
+10 dBm
+10 dBm
1 GHz-18 GHz
+15 dBm
+15 dBm MIN
+7 dBm MIN
5 MHz -18 GHz
VOLTAGE
ANALYZER
CONTROL
IF
AUX LO
FROM TEST SET
10 VOLTS MAX
5 -1500 MHz
1.8-18 GHz
FROM
TO
DOWNCONVERTER
DOWNCONVERTER
TUNE VOLTAGE
OUT OF LOCK
50
20 mA MAX
POWER
Downconverter
GPIB
STATUS
RMT LSN TLK SRQ
ACT
ERR
INPUT
OUTPUT
RF ANALYZER
+5-
+15 dBm
VOLTAGE
CONTROL
IF
AUX LO
10 VOLTS MAX
5 -1500 MHz
1.8-6.6 GHz
Signal input
Downconverted
to be
output to test set
signal input
Agilent E5505A User's Guide

Advertisement

Table of Contents
loading

Table of Contents