Chapter 3 - Commissioning
Table 3-12: SU-ODU LINK QUALITY Bar LEDs Functionality
Bar LEDs
LED 1 (orange) is On
LED 2 (green) is On
LEDs 2-3 (green) are On
LEDs 2-4 (green) are On
LEDs 2-5 (green) are On
LEDs 2-6 (green) are On
LEDs 2-7 (green) are On
LEDs 2-8 (green) a
LEDs 2-9 (green) are On
LEDs 2-9
(green) and 1
are On
3.2.3.3
Verifying Data Connectivity
To verify data connectivity, from the end-user's PC or from a portable PC
connected to the unit, ping a known device in the network, or try to connect to
the
Internet. For units with multiple LAN ports, verify proper operation for each of
the
ports.
82
SNR
The SU is connected with and receives services from
AU/µBST (Network Entry completed)
5dB ≤ SNR < 10dB
10dB ≤ SNR < 15dB
15dB ≤ SNR < 20dB
20dB ≤ SNR < 24dB
SNR ≥ 24 and RSSI < -75
SNR ≥ 24 and RSSI ≥ -75
SNR ≥ 24
re On
SNR ≥ 24 and RSSI ≥ -60
RSSI ≥ -20 (saturation)
0 (red)
and RSSI ≥ -70
BreezeMAX System Manual