3.1.2.2
Base Station LEDs
To verify the correct operation of the Base Station equipment, examine the LED
indicators located on the front panels of the modules. The following
LEDs of the Base Station modules and their associated indications.
Name
PWR
ALARM
WLINK
WACT
SP
IP
ODU1/OD
U2 PWR
ODU1
/ODU2 ALRM
BreezeMAX System Manual
Table 3-3: AU-IDU LEDs
Description
Functionality
Power indication
Alarm indication
Wireless link status
indication
IDU transmission
indication
Spare
Not Used
IP activity indic
ation
IDU to ODU Power
Indication
Base Station and Micro Base Station Commissioning
Off – AU-IDU is not powered
R
ed – AU-IDU power supply failed (low
power)
Green – AU-IDU power is
Off – AU-IDU is OK
Red – AU-IDU failure
Off – No SU is associated
Green – At least one SU is as
Off – No IDU transmission
Green – IDU transmission OK
Off – No downlink (AU to SU) IP
activity
Green (blinking) – Downlink (AU to SU)
IP activity
Off – No IDU to ODU power output
Red – IDU to ODU power output failed
Green – IDU
to ODU power output OK
Off – IDU-ODU communication O
Red - IDU-ODU communication failure
tables list the
OK
sociated
K
73