Legal Rights
cause harmful interference in which case the user will be required to correct the
interference at the user's own expense.
R&TTE Compliance Statement
This equipment complies with the appropriate essential requirements of Article 3
of the R&TTE Directive 1999/5/EC.
Safety Considerations - General
For the following safety considerations, "Instrument" means the BreezeMAX units'
components and their cables.
Grounding
Base Station chassis, Micro Base Station and outdoor units are required to be
bonded to protective grounding using the bonding stud or screw provided with
each unit.
The Micro Base Station shall be bonded to earth at final installation.
Safety Considerations – DC Powered Equipment
CAUTION – Modular Base Station
Risk of electric shock and energy hazard.
Disconnecting one Power Interface Unit (PIU)
disconnects only one PIU module. To isolate the
Modular Base Station completely, disconnect
both PIUs.
Restricted Access Area: The DC powered equipment should only be installed in
a Restricted Access Area.
Installation Codes: The equipment must be installed according to the latest
edition of the country national electrical codes. For North America, equipment
must be installed in accordance with the US National Electrical Code and the
Canadian Electrical Code.
Overcurrent Protection: A readily accessible Listed branch circuit overcurrent
protective device, rated 40A for the modular Base Station or 20A for the Micro
Base Station, must be incorporated in the building wiring.
CAUTION: This equipment is designed to permit connection between the earthed
conductor of the DC supply circuit and the grounding conductor at the
equipment. See installation instructions.
The equipment must be connected directly to the DC Supply System
grounding electrode conductor.
vi
ATTENTION – Station de Base Modulaire
Risque de décharge électrique et
d'electrocution.
La déconnection d'un seul module
d'alimentation (PIU) n'isole pas complètement la
Station de Base Modulaire. Pour cela, il faut
impérativement débrancher les deux modules
d'alimentation (PIU).
BreezeMAX System Manual