Table 3-12: CPE-ODU LINK QUALITY Bar LEDs Functionality
Bar LEDs
LED 1 (WLNK) is On
LED 2 is On
LEDs 2-3 are On
LEDs 2-4 are On
LEDs 2-5 are On
LEDs 2-6 are On
LEDs 2-7 are On
LEDs 2-8 are On
LEDs 2-9 are On
LEDs 2-10 are On
Verifying Data Connectivity
To verify data connectivity, from the end-user's PC or from a portable
PC connected to the unit, ping a known device in the network, or try to
connect to the Internet. For units with multiple LAN ports, verify proper
operation for each of the ports.
Manual Revision 1.0
SNR
SU is connected with and receives services from AU
(Network Entry completed)
5dB ≤ SNR < 10dB
10dB ≤ SNR < 15dB
15dB ≤ SNR < 20dB
20dB ≤ SNR < 24dB
SNR ≥ 24 and RSSI < -75
SNR ≥ 24 and RSSI ≥ -75
SNR ≥ 24 and RSSI ≥ -70
SNR ≥ 24 and RSSI ≥ -60
RSSI ≥ -20 (saturation)
SU Commissioning
3-15