Connecting the Cables

2.1.8.1
Connecting the Grounding Cable
The Grounding screw (marked ╤) is located on the bottom panel of the outdoor
unit.
To connect the grounding cable:
Connect one end of a grounding cable to the grounding screw and tighten the
1
grounding screw firmly.
Connect the other end of the grounding cable to a good ground (earth)
2
connection.
2.1.8.2
Connecting the Antenna Cable
To connect the RF cable (units with external antenna):
Connect one end of the coaxial RF cable to the RF connector (marked
1
located on the bottom panel of the unit.
Connect the other end of the RF cable to the antenna.
2
The RF connectors should be properly sealed to protect against rain and
3
moisture.
2.1.8.3
Connecting the AU-ODU's IF Cable
To connect the IF cable:
Connect one end of the coaxial IF cable to the IF connector on the bottom
1
panel of the unit.
Verify that the length of the IF cable is sufficient to re
2
Base Station. See IF cable length limitation in
BreezeMAX System Manual

Table 2-7: SU-ODU Connectors

Connector
10/100Base-T (RJ-45)
N-Type jack, 50 ohm
Functionality
Connection to the SU-IDU
Connection to an external antenna
ach the AU-IDU/Micro
IF Cab
les
Installing the ODU
)
on page 35.
41