Alvarion BreezeMAX 3500 System Manual page 256

Hide thumbs Also See for BreezeMAX 3500:
Table of Contents

Advertisement

Appendix D - Traps and Alarms
No.
24
25
26
27
D.5.1.3
rbDiagnisticsHwFaultOff Trap
Variable
Sequential Number
Description
Trap Source
Trap Severity
Trap Category
Additional Info
236
rbDiagnisticsHwFaultOn Trap Additional Info
Description
µBST/AU HW fault. When a process to burn IDU table fails (CRC
check on finish fails, FTP session failed, no place in FFS).
µBST/AU HW fault. IF synthesizer failed to lock on the frequency
set on the synthesizer.
µBST/AU HW fault. µBST/AU detected an error while downloading
the OD
U table. The string includes also the byte number of the ODU
table where the error was detected.
µBST/AU HW fault. Connection between µBST/AU and ODU has
been lost.
rbDiagnisticsHwFaultOff Trap Variables
Description
3
A previously detected hardware fault has been fixed.
µBST/NPU/AU/SU
Equipment
Info
3...8, 23...27. For details see Additional Info in
rbDiagnisticsHwFaultOn Trap Additional Info table above.