Each AU (sector) in the network is configured with a unique Base Station ID that
consists of Operator ID, Cell ID and Sector ID. The Base Station ID parame
the SU define the AU(s) that can synchronize with the SU. These parameters
include the 3 components of a base ID for the Base Station (Operator ID, Cell ID,
Sector ID and Base Station ID), and a Base Station ID Mask. The SU can
synchronize only with AUs with a Base Station ID that is included in the IDs
range defined by the applicable parameters in the SU (base ID of the Base Station
that consists of Operator ID, Cell ID and Sector ID, and the Base Station ID
Mask.
The Base Station ID Parameters menu includes the following options:
Show
Operator ID
Cell ID
Sector ID
Base Station ID Mask
B.6.1
Show
Select this option to view the base station ID parameters and the ID of the
connected AU (if applicable). The Base Station ID parameters are applied only
after reset. Therefore, actual values may differ from configured values. For each
parameter both the actual and configured values are displayed:
Operator ID: the base ID of the operator. The unit can synchronize only with
AUs with an Operator ID in the range defined by this Operator ID and the
Operator ID part of the Base Station ID Mask.
Cell ID: the base ID of the cell. The unit can synchronize only with AUs with a
Cell ID in the range defined by this Cell ID and the Cell ID part of the Base
Station ID Mask.
Sector ID: the base ID of the sector. The unit can synchronize only with AUs
with a Sector ID in the range defined by this Sector ID and the Sector ID part
of the Base Station ID Mask.