3.2.3.2
SU – ODU LEDs
To verify the correct operation of the SU – ODU, examine the LED indicators
located on the bottom panel of the outdoor unit.
The following tables list the provided LEDs and their associated indications.
NOTE
Ve fying the correct operation of the Outdoor Unit using the LEDs, as described below, is only
ri
possible after the configuration and alignment processes are completed.
Name
PWR
ALARM
ETH
LINK
QUALITY
bar display
BreezeMAX System Manual

Table 3-11: SU-ODU LEDs

Description
Functionality
Power
indication
Alarm indication
Ethernet link status
indication
(Ethernet integrity)
See Table 3-12.
Wireless link status
and signal quality
Indication
Off – ODU is not p
owered
Green – ODU power is OK
Off – ODU is OK, diagnostic test passed
Red – ODU failure
Off – No Ethernet connectivity has been
detected between the outdoor unit and the
device connected to the indoor unit.
Green– Ethernet connectivity has been
detected between the outdoor unit and the
de
vice connected to the indoor unit