No.
1
2
D.5.1.2
rbDiagnisticsHwFaultOn Trap
Variable
Sequential Number
Description
Trap Source
Trap Severity
Trap Category
Additional Info
No.
3
4
5
6
7
8
23
BreezeMAX System Manual
rbResetOn Trap Additional Info
Description
External Reset
Internal Fault Reset
rbDiagnisticsHwFaultOn Trap Variables
Description
2
The device/card has detected a hardware fault.
µBST/NPU/AU/SU
Major
Equipment
3...8, 23...27 (see details in the following table)
rbDiagnisticsHwFaultOn Trap Additional Info
Description
SU HW fault. Manta's (ASIC) PLL is not locked for more than 5
msec.
SU HW fault. Manta's (ASIC) PLL is not locked in steady state.
SU HW fault. Host failed to download Manta's firmware (complete
with CRC e
rrors, or handshake error).
SU HW fault. Radio's PLL is not locked after power up sequence.
SU HW fault. Radio's PLL is not locked in steady state.
SU, AU, NPU or µBST HW fault. A Built In Test (BIT) has failed.
µBST/AU HW fault. Output Tx Power exceeds PMAX+5dB for more
than 5 minutes.