Table 3-8: Micro Base Station Leds - Alvarion BreezeMAX 3500 System Manual

Hide thumbs Also See for BreezeMAX 3500:
Table of Contents

Advertisement

Chapter 3 - Commissioning
3.1.2.3
Micro Base Station LEDs
To verify the correct operation of the Micro Base Station equipment, examin
LED indicators located on the front panel of the unit. The following table l
LEDs of the Micro Base Station
Name
PWR
ALRM
SP
EXT ALRM
WACT
WLINK
ODU1/ODU2
PWR
ODU1/ODU2
ALRM
3.1.2.4
Verifying the Ethernet Connection
Once you have connected the unit to an Ethernet outlet, verify that the Ethernet
Integrity Indicator, which is the yellow LED embedded in the DATA port
connector, is on. This indicates that the unit is connected to an Ethernet
segment. The Ethernet Activity Indicator, which is the green embedded LED,
should blink whenever the unit receives or transmits traffic on the DATA port.
76

Table 3-8: Micro Base Station LEDs

Description
Power indication
Micro Base Station alarm
indication
Spare
External alarm indication
IDU transmission indication
Wireless link status
indication
IDU to ODU Power
Indication
IDU-ODU communication
status
and their associated indications.
Functionality
Off – Micro B
ase Station is not
powered
Red – Input power fai
Green – Micro Base Station power i
OK
Off –Micro Base Station is OK
Red – Micro Base Station failure
Not Used
Red – External alarm (received via the
ALRM IN port). Not applicable in the
current release.
Off – No IDU transmission
Green – IDU transmission OK
Off – No SU is associated
Green – At least one SU is associated
Off – No IDU to ODU power output
Red – IDU to ODU power output failed
Green – IDU to ODU power output OK
Off – IDU-ODU communication OK
Red - IDU-ODU communication failure
e the
ists the
lure
s